safety interlock switches -6
This heavy-duty safety interlock switch is designed for high-risk machinery and large access points. It features a robust, key-operated locking mechanism to ensure dangerous equipment cannot operate unless the guard is fully secured, providing maximum personnel protection.
Product | Safety Door Switch NST11 | ||
Electromagnetic tube | |||
Rated operating voltage | DC24V | ||
Power | 4.8W | ||
Rated current | Approximate 200mA | ||
Insulation | Class B (130°C) | ||
Protection rate | IP67 | ||
LED indicator | |||
Rated operating voltage | DC24V | ||
Rated current | Approximate 1mA | ||
Luminous color (LED) | Green | ||
Electrical parameters | |||
Contact resistance | < 200 mΩ | ||
Nominal discharge current (lth) | 10A | ||
Rated insulation voltage (Ui) | 300V | ||
Anti-electric shock level | Class II (Dual Insulation) | ||
Pulse withstand voltage (EN60947-5-1) | 2.5KV | ||
Insulation resistance | 100MΩ above | ||
Short-circuit protection | 10A, 250V requires a quick-break fuse | ||
Vibration resistance | 10-55Hz double amplitude 1.5mm | ||
Impact resistance | Durability1000m/s2 | ||
Conditional short-circuit current | 100A (EN 60947-5-1) | ||
Space of contact | 2×2mmabove | ||
Action characteristic | |||
Direct opening force | Min. 60N | ||
Direct opening travel | Over 10mm | ||
Allowed operating speed | 0.1 m ~ 0.5m/s | ||
Allowed operating frequency | Maximum 30 times/minutes | ||
Holding force | 1300N | ||
Environment | |||
Operating environment | 3 (EN60947-5-1) | ||
Operating temperature | -10℃~+55℃ (no freezing) | ||
Operating humidity | < 95%RH |